<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Sprinklers and Electrical Equipment</title>
	<atom:link href="http://www.iaei.org/magazine/?feed=rss2&#038;p=4258" rel="self" type="application/rss+xml" />
	<link>http://www.iaei.org/magazine/?p=4258&amp;utm_source=rss&amp;utm_medium=rss&amp;utm_campaign=sprinklers-and-electrical-equipment</link>
	<description>The definitive magazine for electrical inspectors</description>
	<lastBuildDate>Thu, 02 Sep 2010 03:49:56 +0000</lastBuildDate>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
	<item>
		<title>By: Kevin Manchur</title>
		<link>http://www.iaei.org/magazine/?p=4258&#038;cpage=1#comment-57</link>
		<dc:creator>Kevin Manchur</dc:creator>
		<pubDate>Mon, 19 Oct 2009 21:56:04 +0000</pubDate>
		<guid isPermaLink="false">http://www.iaei.org/magazine/?p=4258#comment-57</guid>
		<description>I am also a Electrical Safety Codes Officer and strongly agree with Grant Manchur&#039;s comment. The ABC fire extinguisher (dry chemical and &quot;C&quot; for electrical equipment ) is what is found in most electrical rooms not water extinguishers!</description>
		<content:encoded><![CDATA[<p>I am also a Electrical Safety Codes Officer and strongly agree with Grant Manchur&#8217;s comment. The ABC fire extinguisher (dry chemical and &#8220;C&#8221; for electrical equipment ) is what is found in most electrical rooms not water extinguishers!</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Grant Manchur -ESCO</title>
		<link>http://www.iaei.org/magazine/?p=4258&#038;cpage=1#comment-56</link>
		<dc:creator>Grant Manchur -ESCO</dc:creator>
		<pubDate>Mon, 19 Oct 2009 19:52:28 +0000</pubDate>
		<guid isPermaLink="false">http://www.iaei.org/magazine/?p=4258#comment-56</guid>
		<description>As an ESCO and 36 great years in the electrical industry l disagree with &#039;water&#039; as a form of measure for extinguishing fires in electrical rooms where general purpose equipment (not water tight rated T.65). In my opinion the extinguisher  should be equivalent to a &#039;halon&#039; substance. Why?-because if a maintenance personnel is in the electrical room when a water sprinkler head is activated and if the person is working on energized equipment (which a qualified electrician is authorized to do) chances are very likely electrocution may occur. I realized there are other standards that differ but why do we have 2-024 in the CEC C22.1-09 if its not followed. And if its not followed there is a deviance to this rule then a variance from the Safety Council should be issued. PS-l wonder what the equivalent of safety would be if there was a variance issued? 

My 2 cents worth.</description>
		<content:encoded><![CDATA[<p>As an ESCO and 36 great years in the electrical industry l disagree with &#8216;water&#8217; as a form of measure for extinguishing fires in electrical rooms where general purpose equipment (not water tight rated T.65). In my opinion the extinguisher  should be equivalent to a &#8216;halon&#8217; substance. Why?-because if a maintenance personnel is in the electrical room when a water sprinkler head is activated and if the person is working on energized equipment (which a qualified electrician is authorized to do) chances are very likely electrocution may occur. I realized there are other standards that differ but why do we have 2-024 in the CEC C22.1-09 if its not followed. And if its not followed there is a deviance to this rule then a variance from the Safety Council should be issued. PS-l wonder what the equivalent of safety would be if there was a variance issued? </p>
<p>My 2 cents worth.</p>
]]></content:encoded>