Not just in print, the current issue of IAEI News is also available online. January/February 2010 is available now for you to flick through from cover to cover online! Try it out and give us your feedback. We would love to know what you think. But remember, you can’t collect a website… Edited on February [...]

1 Star2 Stars3 Stars4 Stars5 Stars (3 votes, average: 4.33 out of 5)
Photos 1–3. These images, which were supplied by a senior electrical inspector from Peoria, Arizona, illustrate an electrical fire due to damaged conductors. The extensive charring illustrates one of the reactions that wood has to excessive temperatures. The wood is not only charring but also dehydrating, expelling gases due to molecules breaking down in the elevated temperatures. Nearby materials are at an increased risk of ignition.

Safety in Our States

[ 4 ] By  |  January 22, 2010  |  IAEI January-February 2010

We should all be champions of electrical safety and strive to ensure that our customers, our friends and our families do not experience the worst that electricity has to offer. In the words of Wesley Smith of Mount Lebanon, Pennsylvania, who almost had a major incident, “Fire is something that you definitely don’t want to [...]

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
GFCI Receptacle

The Illusion of GFCI Protection


During the required annual pool inspections for commercial indoor pools, the inspector happened upon a ground-fault circuit-interrupter (GFCI) device, with a water cooler connected but without a cover plate. Using his tester it was discovered that the GFCI device protecting the receptacle failed to trip. Expanding the test to all GFCI devices around the pool, [...]

1 Star2 Stars3 Stars4 Stars5 Stars (4 votes, average: 4.50 out of 5)
Photo 1.  Modern explosionproof equipment

Hazardous Area Classification: Division or Zone — You Do Have a Choice

[ 1 ] By  |  January 22, 2010  |  IAEI January-February 2010

OK all you sports fans out there, it’s football season; and everyone is fired up and running out to buy the latest item of team gear to show their support. But, hey, wait just a minute; your team did real well last season, but maybe it’s time to make a different choice for this season. [...]

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
PV Utility Connections

Supply-side PV Utility Connections

[ 0 ] By  |  January 21, 2010  |  IAEI January-February 2010

Many larger PV systems cannot meet the requirements for a load-side (of the service disconnect) connection to the premises wiring system and a supply-side connection must be considered. Code Considerations The supply-side connection (also known as a service-entrance tap) is allowed by the National Electrical Code (NEC) and is addressed in a number of sections [...]

1 Star2 Stars3 Stars4 Stars5 Stars (3 votes, average: 4.67 out of 5)
Electric sign

Do you inspect and approve electric signs? Things you may want to know about your authority

[ 0 ] By  |  January 21, 2010  |  IAEI January-February 2010

In most jurisdictions in this country, there has been implemented some version of a building code. Beyond the quality and safety issue, the electric sign or outline lighting installation shall comply with the building code. The building code, which is either adopted by local ordinance or by state mandate, requires electrical utilization equipment (electric signs) [...]

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)
Outdoor generator

A New Generation

[ 0 ] By  |  January 21, 2010  |  IAEI January-February 2010

A former student called me to ask how to size a new generator for a facility. He said the calculated load would be 1200 amps at 277/480 three-phase four-wire. It would be used for supplying power when the normal electrical supply system is interrupted. This would include lighting for general illumination, for life support equipment [...]

1 Star2 Stars3 Stars4 Stars5 Stars (2 votes, average: 3.50 out of 5)
Photo 1. This view shows the hills of Kinglake where the fire passed through and it is encouraging to see the grass that has re-grown. All the hills in the photo suffered and, as you have heard, many homes and businesses were lost.

Electrical Installations After the Fire

[ 0 ] By  |  January 13, 2010  |  IAEI January-February 2010

Australia is a country that has a variety of terrains from the tropical regions of the north to the mountains in the south. In February 2009, Victoria experienced one of the natural disasters that result from bushfires that become out of control. All of Victoria had reached the 40°C (104°F) temperatures in many areas by [...]

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)

Was the Fire Protection Research Foundation’s (FPRF) Residential Electrical System Aging Research Project completed?


Question I  understand UL conducted research on old homes to determine the effects of aging on residential electrical wiring systems. Is that research project complete, and where can I get the report and any recommendations from the research?

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)

Do Stacked AFCIs Cause Panelboards to Overheat?


Question I have noticed that arc-fault circuit-interrupter (AFCI) circuit breakers tend to be warmer to the touch than regular circuit breakers. Now that the 2008 NEC requires most circuits in a dwelling to be protected by a combination-type AFCI circuit breaker, and there will be more AFCIs stacked into a panel, will the added heat [...]

1 Star2 Stars3 Stars4 Stars5 Stars (No Ratings Yet)