January/February 2010
Not just in print, the current issue of IAEI News is also available online. January/February 2010 is available now for you to flick through from cover to cover online! Try it out and give us your feedback. We would love to know what you think. But remember, you can’t collect a website… Edited on February [...]
We should all be champions of electrical safety and strive to ensure that our customers, our friends and our families do not experience the worst that electricity has to offer. In the words of Wesley Smith of Mount Lebanon, Pennsylvania, who almost had a major incident, “Fire is something that you definitely don’t want to [...]
During the required annual pool inspections for commercial indoor pools, the inspector happened upon a ground-fault circuit-interrupter (GFCI) device, with a water cooler connected but without a cover plate. Using his tester it was discovered that the GFCI device protecting the receptacle failed to trip. Expanding the test to all GFCI devices around the pool, [...]
OK all you sports fans out there, it’s football season; and everyone is fired up and running out to buy the latest item of team gear to show their support. But, hey, wait just a minute; your team did real well last season, but maybe it’s time to make a different choice for this season. [...]
Many larger PV systems cannot meet the requirements for a load-side (of the service disconnect) connection to the premises wiring system and a supply-side connection must be considered. Code Considerations The supply-side connection (also known as a service-entrance tap) is allowed by the National Electrical Code (NEC) and is addressed in a number of sections [...]
In most jurisdictions in this country, there has been implemented some version of a building code. Beyond the quality and safety issue, the electric sign or outline lighting installation shall comply with the building code. The building code, which is either adopted by local ordinance or by state mandate, requires electrical utilization equipment (electric signs) [...]
A former student called me to ask how to size a new generator for a facility. He said the calculated load would be 1200 amps at 277/480 three-phase four-wire. It would be used for supplying power when the normal electrical supply system is interrupted. This would include lighting for general illumination, for life support equipment [...]
Australia is a country that has a variety of terrains from the tropical regions of the north to the mountains in the south. In February 2009, Victoria experienced one of the natural disasters that result from bushfires that become out of control. All of Victoria had reached the 40°C (104°F) temperatures in many areas by [...]
Question I understand UL conducted research on old homes to determine the effects of aging on residential electrical wiring systems. Is that research project complete, and where can I get the report and any recommendations from the research?
Question I have noticed that arc-fault circuit-interrupter (AFCI) circuit breakers tend to be warmer to the touch than regular circuit breakers. Now that the 2008 NEC requires most circuits in a dwelling to be protected by a combination-type AFCI circuit breaker, and there will be more AFCIs stacked into a panel, will the added heat [...]