Photo 1. Ultra-low harmonic drives feature bypass valve, fuse disconnect, remote I-O and selector switches.

Critical Systems Case Study: Ultra-Low Harmonic Drives Protect Transformers and Power Grid

[ 0 ] By  |  September 7, 2007  |  IAEI September-October 2007

According to the United States Geological Survey, the average American uses about 100 gallons of water each day. This, in turn, creates more than 31 billion gallons of wastewater, which is cleaned and recycled by wastewater treatment plants across the country. Under the Homeland Security Act, wastewater facilities play a critical role in the needs [...]

1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Figure 1

VFDs for Energy Savings in Hospitals – what they are, how they work, and how they save money

[ 0 ] By  |  July 13, 2006  |  IAEI July-August 2006

What Is a VFD? A variable frequency drive (VFD) is an electrical device we use to control the speed of a standard three-phase ac induction motor. The number of poles designed into a motor and the frequency applied to the motor determine the motor base speed. We can conveniently adjust the speed of a motor [...]

1 Star2 Stars3 Stars4 Stars5 Stars (2 votes, average: 5.00 out of 5)
Figure 1

The 3rd Harmonic Blocking Filter: A Well Established Approach to Harmonic Current Mitigation


It  has long been recognized that harmonic currents, particularly the 3rd harmonic, flowing in a wye distribution system serving multiple computer loads, are detrimental to system operation. Problems caused by these harmonic currents include overheated transformers, switchgear and wiring; random circuit breaker tripping; and reduced useable system capacity. Conventional methods used to mitigate the harmful [...]

1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Figure 1. Typical installation of 3rd harmonic blocking filter

3rd Harmonic Blocking Filter: Is the Cure Worse Than the Disease?

[ 0 ] By  |  September 4, 2002  |  IAEI September-October 2002

It is commonly known that conventional transformers and neutral conductors can become overloaded and hot due to harmonics generated by computer equipment and other non-linear loads. Triplen current harmonics (mainly 3rd and 9th) sum arithmetically in the neutral and circulate in the primary windings of transformers. A simple and effective solution being commonly applied is [...]

1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)